Price : Rp35.000.000
Combustion AnalyserThe KANE900 PLUS handheld
analyser is easy to use for domestic and industrial boiler flue gas
measurement and analysis. It operates on all boiler types and can
display 8 parameters simultaneously showing measurements and
calculations of boiler efficiency and pollution.
Measures O2, flue and nett temperature and calculates CO2, boiler efficiency, excess air and losses.
CO is measured with a hydrogen compensated sensor for increased accuracy.
It
also measures CO and calculates CO/CO2 ratio - ‘The Poison Index’ - to
give complete readings for effective boiler analysis and safety.
Measures NO and calculates NOx.
Big character display
IR printer link... printed header can be customised
Large memory to store results for easy transfer to PC
Long life battery recharged in situ
Product Features :
- Full combustion analyser with infra-red output to optional printer.
- 'Standard' instrument measures O2, CO (hydrogen compensated),
- Temperature and differential pressure.
- Can be upgraded with up to two additional toxic sensors.
- Calculates CO2, CO/CO2 ratio, excess air and efficiency for all fuels.
- Fitted with rubber sleeve and rechargeable battery.
Kit contents:
- Analyser with rubber protective sleeve
- Carry case.
- Charger
- KMCP10 flue probe
Specification :
Parameter |
Resolution |
Accuracy |
Range |
Temp Measurement |
Flue Temperature |
0.1°C/F |
+2.0°C +0.3% reading |
0-1200°C/32 -2200°F with suitable probe |
Inlet Temperature |
0.1°C/F |
+1°C +0.3% reading |
0-50°C/32-122°F |
Pressure (optional) |
0.1mbar |
+2% of full scale |
+150mbar to -150mbar |
Gas Measurement *1 |
Oxygen |
0.1% |
+0.2% |
0-25% |
Carbon Monoxide (standard H compensated) |
1ppm |
+20ppm <400ppm +5% <5000ppm +10% >5000ppm |
0-10,000ppm, |
Carbon Monoxide, (high range) |
0.01% |
+5% reading from 0.1% to 10% |
0-10% |
Nitric Oxide (standard) |
1ppm |
+5ppm <100ppm*1 +5% >100ppm |
0-5000ppm |
Nitrogen Oxide (low range) |
1ppm |
+2ppm <30ppm +5ppm >30ppm |
0-1000ppm |
Nitrogen Dioxide |
1ppm |
+5ppm <100ppm +10ppm <5000ppm +10% >500ppm |
0-100ppm |
Sulphur Dioxide |
1ppm |
+5ppm <100ppm +5% >100ppm |
0-500ppm |
Calculations |
Carbon Dioxide*2 |
0.1% |
+0.3% reading |
0-99.9% |
Losses |
0.1% |
+1.0% reading |
0-99.9% |
Efficiency |
0.1% |
+1.0% reading |
0-99.9% |
Excess Air |
0.1% |
+0.2% |
0-2885.0% |
Temp (Nett) |
1.0°C/F |
+2°C +0.3% reading |
0-600°C/32-1112°F |
CO/CO2 ratio |
0.0001 |
+0.0001 |
0-0.9999 |
Poison Index |
0.01% |
+0.01 |
0-99.99 |
*1 Using dry gases at STP
*2 Calculated
Parameter |
Description |
Pre-programmed Fuels |
Natural gas, Town gas, Gascor, Light Oil, Heavy Oil, Propane, Butane, Anthracite, Coke, Coal, Kinsale Gas. |
Dimensions Weight |
1kg |
Handset |
220mm x 55mm x 120mm |
Probe |
L240mm x Dia8mm with 285mm long stainless steel shaft, type K thermocouple and 1.5m long neoprene hose
|
Ambient Operating Range |
-5°C to +50°C/10% to 90% RH non condensing |
Power Supply (battery charger) |
Input: 110Vac/220 Vac nominal Output: 12 Vac off load |
Battery Life |
>6 hours from full charge |
Untuk Pemesanan segera hubungi :
Contact : Aditya Kurniawan
Telpon : 02199317739 / 085716241676 / 082110947526
email : adit.knt@gmail.com
YM : cs_knt1
Blog : karyanusatama.blogspot.com
Indonetwork : indonetwork.co.id/kntonlinestore
Website : www.karyanusatama.com
Alamat : Jl. Masjid Darussalam RT14/RW11 No.2 Gg.Langgar 2 Kedaung - Pamulang, Tangerang Selatan Banten, 15415