ES Series
Topcon’s new ES Series Total Stations – New Advanced Design with Superior Technology
The new ES Series was designed from the ground up to deliver the very latest technology advantages, all in a small, sleek design – you’ll appreciate the advantages from the very first measurement.
Featuring a class leading EDM unit, the ES is able to measure up to 4,000m to standard prisms, and can measure in reflectorless mode up to 500m at an incredible 3mm + 2ppm accuracy.
Measurements are carried out faster than ever, and at 15mm (over 30m), the bright red laser dot pinpoints features with ease.
*1 Operating time may vary depending on environmental conditions and type of work being performed.
The new ES Series was designed from the ground up to deliver the very latest technology advantages, all in a small, sleek design – you’ll appreciate the advantages from the very first measurement.
Featuring a class leading EDM unit, the ES is able to measure up to 4,000m to standard prisms, and can measure in reflectorless mode up to 500m at an incredible 3mm + 2ppm accuracy.
Measurements are carried out faster than ever, and at 15mm (over 30m), the bright red laser dot pinpoints features with ease.
World’s First TSshield™ Remote Security and Notification System
|
|
Ultra-Powerful, Advanced EDM
|
|
The exclusive LongLink™ communications functionality in every ES Series model provides operational capabilities never before offered in a manual total station. With a 300m range wireless communication using Bluetooth Class 1 technology, you can now operate the data collector from the “smart-spot” of the crew, the prism pole. Also referred to the two-man, economical robot solution, Topcon’s new LongLink™ technology brings a whole new level of flexibility to your manual field crew. |
|
Advanced Angle Encoder System
|
|
Ultimate in Rechargeable operation - 36 Hours!
|
|
Rugged, Waterproof Design
|
|
Easy Access USB 2.0 Memory
|
Specification :
Telescope | |
Magnification / Resolving power : | 30x / 2.5” |
Others : | Length: 171mm (6.7in.), Objective aperture: 45mm (1.8in.) (48mm (1.9in.) for EDM), Image: Erect, Field of view: 1°30’ (26m/1,000m), Minimum focus: 1.3m (4.3ft.), Reticle illumination: 5 brightness levels |
Angle measurement | |
Display resolution : | 0.5” / 1” (0.0001 / 0.0002gon, 0.002 / 0.005mil) |
Accuracy (ISO 17123-3:2001) : | 1” |
IACS (Independent Angle Calibration System) : | Provided |
Dual-axis compensator / Collimation compensation : | Dual-axis liquid tilt sensor, working range: ±6’ (±111mgon) / Collimation compensation available |
Distance measurement | |
Laser output *1 : | Reflectorless mode: Class 3R / Prism / sheet mode: Class 1 |
Measuring range (under average conditions*2) | |
Reflectorless*3 : | 0.3 to 500m(1.0 to 1,640ft.) |
Reflective sheet*4/*5 : | RS90N-K: 1.3 to 500m (4.3 to 1,640ft.) RS50N-K: 1.3 to 300m (4.3 to 980ft.), RS10N-K: 1.3 to 100m (4.3 to 320ft.) |
Mini prisms : | CP01: 1.3 to 2,500m (8,200ft.), OR1PA: 1.3 to 500m (1,640ft.) |
One AP prism : | 1.3 to 4,000m (4.3 to 13,120ft.) / Under good conditions*6: 5,000m (16,400ft.) |
Three AP prisms : | to 5,000m (16,400ft.) / Under good conditions*6: to 6,000m (19,680ft.) |
Display resolution : | Fine/Rapid: 0.001m / 0.01ft. / 1/8in. Tracking: 0.01m / 0.1ft. / 1/2in. |
Accuracy*2 (ISO 17123-4:2001) (D=measuring distance in mm) | |
Reflectorless*3 : | (3 + 2ppm x D) mm*7 |
Reflective sheet*4 : | (3 + 2ppm x D) mm |
AP/CP prism : | (2 + 2ppm x D) mm |
Measuring time*8 : | Fine: 0.9s (initial 1.7s), Rapid: 0.7s (initial 1.4s), Tracking: 0.3s (initial 1.4s) |
Interface and Data management | |
Display / Keyboard : | Graphic LCD, 192 x 80 dots, backlight, contrast adjustment / Alphanumeric keyboard / 25 keys with backlight |
Control panel location*9 : | On both faces |
Trigger key : | On right instrument support |
Data storage | |
Internal memory : | Approx. 10,000 points |
Plug-in memory device : | USB flash memory (max. 8GB) |
Interface : | Serial RS-232C, USB2.0 (Type A, for USB fl ash memory) |
Bluetooth modem (option)*10 : | Bluetooth Class 1, Ver.2.1+EDR, Operating range: up to 300m (980ft.)*11 |
General | |
Laser-pointer*12 : | Coaxial red laser using EDM beam |
Guide light*12 : | Green LED (524nm) and Red LED (626nm), Operating range: 1.3 to 150m (4.3 to 490ft.) |
Levels | |
Graphic : | 6’ (Inner Circle)T |
Circular level : | 10’ / 2mm |
Optical plummet : | Magnification: 3x, Minimum focus: 0.3m (11.8in.) from tribrach bottom |
Laser plummet (option) : | Red laser diode (635nm±10nm), Beam accuracy: <=1.0mm@1.3m, Class 2 laser produc |
Dust and water protection : | IP66 (IEC 60529:2001) |
Operating temperature*13 : | -20 to +50°C (-4 to +122°F) |
Size with handle*8 : | Control panel on both faces: W191 x D181 x H348mm (W7.5 x D7.1 x H13.7in.) |
Weight with handle and battery : | Approx. 5.6kg (12.3 lb.) |
Power supply | |
Battery (BDC70 detachable battery) | Li-ion rechargeable battery |
Operating time (20°C) | |
BDC70 : | Approx. 36 hours (single distance measurement every 30 seconds) |
External battery (option) : | BDC60: approx. 44 hours, BDC61: approx. 89 hours (single distance measurement every 30 seconds) |
*1 IEC60825-1:Ed.2.0:2007 / FDA CDRH
21 CFR Part 1040.10 and 11 *2 Average conditions: Slight haze,
visibility about 20km (12 miles), sunny periods, weak scintillation. *3
With Kodak Gray Card White Side (90% refl ective). When brightness on
measured surface is 30,000 lx. or less. Refl ectorless range/accuracy
may vary according to measuring objects, observation situations and
environmental conditions. *4 When the measuring beam’s incidence angle
is within 30° in relation to the refl ective sheet target. *5 Measuring
range in temperatures of -30 to -20°C (-22 to -4°F) with Low Temperature
models and 50 to 60°C (122 to 140°F) with High Temperature models:
RS90N-K: 1.3 to 300m (4.3 to 980ft.), RS50N-K: 1.3 to 180m (4.3 to
590ft.), RS10N-K: 1.3 to 60m (4.3 to 190ft.) *6 Good conditions: No
haze, visibility about 40km (25 miles), overcast, no scintillation. *7
Measuring range:0.3 to 200m *8 Typical, under good conditions. Refl
ectorless measurement time may vary according to measuring objects,
observation situations and environmental conditions. *9 Control panel
location may vary depending on region or model. *10 Usage approval of
Bluetooth wireless technology varies according to country. Please
consult your local offi ce or representative in advance. *11 No
obstacles, few vehicles or sources of radio emissions/interference in
the near vicinity of the instrument, no rain. *12 The laser-pointer and
the guide light do not work simultaneously. *13 Low Temperature
models:-30 to 50° C (-22 to 122°F) and High Temperature models:-20 to
60°C (-4 to 140¬∞°F, No direct sunlight) are available on built-to-order
basis.
Untuk Pemesanan segera hubungi :
Contact : Aditya Kurniawan
Telpon : 02199317739 / 085716241676 / 082110947526
email : adit.knt@gmail.com
YM : cs_knt1
Blog : karyanusatama.blogspot.com
Indonetwork : indonetwork.co.id/kntonlinestore
Website : www.karyanusatama.com
Contact : Aditya Kurniawan
Telpon : 02199317739 / 085716241676 / 082110947526
email : adit.knt@gmail.com
YM : cs_knt1
Blog : karyanusatama.blogspot.com
Indonetwork : indonetwork.co.id/kntonlinestore
Website : www.karyanusatama.com
Tidak ada komentar:
Posting Komentar